eTigris®|TWO access control system networked doors, step by step specification guide
eTigris®|TWO.220 supports up to 10,000 users and 128 networked doors and is therefore ideal for small to medium size systems. For larger projects, please contact our sales office for further assistance.
In addition to these guides assistance can be sought please email enquiries@access2.com or contact sales on 0191-215-0530.
The eTigris®|TWO.220 access control equipment uses RFID (Radio Frequency Identification) technology consisting of an accessible reader unit mounted adjacent to the door, a control unit mounted in a convenient cupboard or ceiling void and an access credential which transmits an electronic ID to the reader.

- Up to 10,000 individual users
- Up to 128 networked doors
To specify a network door access control solution, please follow the seven step process below. The steps can also be downloaded here.
|
Step 1: Select the PC & Software |
|||||
|
eTigris®|TWO PC Control for Networked Doors |
Qty to specify |
When to specify |
Notes |
||
|
eTigris®|TWO.220 software & registration reader |
eTigris®|TWO WindowsTM software & registration reader. The registration reader is required to add credentials to the system |
1 |
One required per system |
Compatible with Microsoft XP Professional or Vista Business / Premium |
![]() |
|
Computer (PC) |
PC running Microsoft XP Professional or Vista Business / Premium. Minimum specification - 2 or more service processors, 4Gb of free RAM for use of the database server only, 320Gb of disc space with a display of 1024 x 768 |
1 |
One required per system |
Dedicated PC not mandatory yet is recommended (see technical alert) |
![]() |
| Technical Alert: Whilst a dedicated PC is not mandatory, it is recommended as, for example, your system is not likely to be disrupted by the later addition of other software programs | |||||
| 1 | |||||
|
Step 2: Select how the user will enter & exit the door |
|||||
|
eTigris®|TWO Readers & Exit Buttons |
Qty to specify |
When to specify |
Notes |
||
|
eTigris®|TWO Weigand reader |
Accessible control reader for use with the eTigris®|TWO system. For use with eTouch credentials only. Supplied with chrome, black & yellow interchangeable end caps. Reader is suitable for internal or sheltered external applications |
1 or 2 per door |
One required per door (or two per door if read in / read out is required). Device operated by eTouch Key or eTouch Fob |
n/a |
![]() |
|
eTigris®|TWO UHF receiver |
eTigris®|TWO UHF receiver for use with eButton transmitter. Can be mounted internally or externally |
1 per door |
Only when long range control is required. Device is operated by eButton (see below). One required per door. Not suitable for read in / read out applications |
See technical alert below |
![]() |
|
EA ANRTESP |
Request to exit switch, single gang, surface mounted, white plastic |
1 per door |
For medium duty applications |
n/a |
![]() |
|
EA ANRTEF 02 |
Request to exit switch, single gang, flush mounted, stainless steel |
1 per door |
For heavy duty applications |
n/a |
![]() |
|
EA ANBGSDPR |
Green break glass, surface mounted - double pole - resettable |
1 per door |
Specify if door is a FIRE EXIT or crosses a fire route |
See technical alert below |
![]() |
|
Flush Vandal Resistant Kit |
Kit that provides vandal resistance and or resistance from water to eTigris®|TWO readers - flush mounted. Reader not included |
1 per external door |
Specify one per external door that is to be controlled by an eTigris®|TWO Weigand reader |
n/a |
![]() |
|
Surface Vandal Resistant Kit |
Kit that provides vandal resistance and or resistance from water to eTigris®|TWO readers - surface mounted. Reader not included |
1 per external door |
Specify one per external door that is to be controlled by an eTigris®|TWO Weigand reader |
n/a |
![]() |
|
Technical Alert: The field strength and range of an eButton transmitter is largely dependent upon the building structure and environment. When activated, the eButton transmits a UHF signal that is multi directional and therefore will activate all compatible receivers within its range. The user of the eButton transmitter may therefore unintentionally activate multiple openings. To avoid this, UHF receivers should be located a minimum distance of 150m apart. Doors fitted with access control that cross a fire route or are classed as a fire exit should integrate to the fire alarm system so when activated fail in the open or unlocked state. Please refer to the Access Control Design Guide or consult your local fire officer and building control officer. |
|||||
| 2 | |||||
|
Step 3: Select the quantity of door control units to support step 2 choices |
|||||
|
eTigris®|TWO Door Control Units |
Qty to specify |
When to specify |
Notes |
||
|
eTigris®|TWO.220 system controller |
eTigris®|TWO system door controller in mild steel cabinet with 2amp PSU. The PSU has 1amp free for electric locking and exit devices |
1 per two readers / UHF receivers |
1 Per door using read in/read out, or 1 per pair of doors using read in only |
See technical alert below |
![]() |
|
Technical Alert: Readers can be located up to a maximum of 100m from the system controller, if a reader is further than 100m from the controller then an additional controller is required. If in doubt please state that your specification is SUBJECT TO SURVEY. |
|||||
| 3 | |||||
|
Step 4: Select how the doors shall be locked |
|||||
|
eTigris®|Electro Magnetic Locks |
Qty to specify |
When to specify |
Notes |
||
|
EA ML1000 |
eTigris® mini magnet, 600lbs holding force |
1 per door |
Single outward opening door, low security applications |
Lock surface mount on the underside of the head frame, with the armature fixed to the face of the door |
![]() |
|
EA ML1002 |
eTigris® double mini magnet, 600lbs holding force |
1 per door |
Double outward opening door, low security applications |
Lock surface mount on the underside of the head frame, with the armature fixed to the face of the door |
![]() |
|
EA ML1000L |
eTigris® L bracket for mini magnet |
1 per door |
Allows ML1000 lock to be fitted to a single outward opening door |
where door is flush with the frame (2 required for ML1002) |
![]() |
|
EA ML1000ZL |
eTigris® Z & L bracket for mini magnet |
1 per door |
Allows ML1000 lock to be fitted to a single inward opening door |
(2 required for ML1002) |
![]() |
|
EA ML1100 |
eTigris® standard magnet, 1200lbs holding force |
1 per door |
Single outward opening door, medium security applications |
Lock surface mount on the underside of the head frame, with the armature fixed to the face of the door |
![]() |
|
EA ML1102 |
eTigris® Double standard magnet, 1200lbs holding force |
1 per door |
Double outward opening door, medium security applications |
Lock surface mount on the underside of the head frame, with the armature fixed to the face of the door |
![]() |
|
EA ML1100L |
eTigris® L bracket for standard magnet |
1 per door |
Allows ML1100 lock to be fitted to a single outward opening door |
where door is flush with the frame (2 required for ML1102) |
![]() |
|
EA ML1100ZL |
eTigris® Z & L bracket for standard magnet |
1 per door |
Allows ML1000 lock to be fitted to a single inward opening door |
(2 required for ML1102) |
![]() |
| 4 | |||||
|
Step 5: Select any additional PSU(s) |
|||||
|
eTigris®|Power Supplies |
Qty to specify |
When to specify |
Notes |
||
|
Technical Alert: Additional PSUs may be required! Each system controller has the capacity to provide a maximum of 1Amp (1000mA) to electronic locking and request to exit devices. If this amount is exceeded, please use additional power supply units as required. For further information on sizing the correct PSU please refer to the Access Control Design Guide or contact us for further assistance. |
|||||
|
EA ANPSU1 |
Power supply unit, 12V DC - 1Amp. steel boxed |
1 per door controller |
Specify 1 for each door controller when less than 1 Amp of additional current capacity is required |
n/a |
![]() |
|
EA ANPSU2 |
Power supply unit, 12V DC -2 Amp. steel boxed |
1 per door controller |
Specify 1 for each door controller when less than 2 Amps of additional current capacity is required |
n/a |
|
|
EA ANBAT7 |
Back-up battery, 12V - 7 Ampere/hour |
1 per PSU |
Specify 1 for each PSU specified |
All electro magnetic locks are fail open. In the event of power failure the door will unlock. A battery will provide emergency power for a limited period |
|
| 5 | |||||
|
Step 6: Select the user credentials |
|||||
|
eTigris®| Credentials |
Qty to specify |
When to specify |
Notes |
||
|
eTouch Key |
Accessible control credential. Supplied with a Tigris® Premier or Omega key (Please specify key details & add the cost of the key) |
1 per user |
Add up all of the users that require an eTouch Key |
n/a |
![]() |
|
eTouch Fob |
Accessible control credential. Can be upgraded later to incorporate a Tigris® Premier or Omega key |
1 per user |
Add up all of the users that require an eTouch Fob |
n/a |
![]() |
|
eButton Transmitter |
Accessible control credential. Push button remote transmitter for use with eTigris®|TWO UHF Receiver |
1 per user |
Add up all of the users that require an eButton. Used only with eTigris®|TWO UHF receiver |
eTigris®|TWO UHF receiver must be included within the system |
![]() |
|
eTouch Key Upgrade Pack |
Converts Tigris® Premier or Omega key to an eTouch Key. Please specify Premier or Omega. (Only a screwdriver is required) |
See Notes |
Specify only when existing Tigris® Premier or Omega keys exist that require upgrade to eTouch Key |
n/a |
![]() |
|
eTouch Fob Upgrade Pack |
Converts eTouch Fob to accept a Tigris® Premier or Omega key and thus become an eTouch Key. Please specify key details. (Only a screwdriver is required) |
See Notes |
Specify only when existing eTouch Fobs exist that require upgrade to eTouch Key |
n/a |
![]() |
Further power supplies, push to exit devices & electronic locking options are available please email enquiries@access2.com or contact sales on 0191-215-0530 further details.
The UK's most specified masterkey system just got integrated... mechanical AND electric locking. in one cost-effective system.